Mark Ballard LTD
Mark Ballard LTD
  • 118
  • 6 819 385
How to Repair Leaking Blanking Plugs & How to Install new Ones, Important Things You Must Do!!
Very important things you must do when repairing or installing new radiator air vents and blanking plugs. Other wise you may find they stat leaking in some years to come. No one wants any Leaks.
I will show you with step by step easy to follow instructions how to do this with little fuss or mess.
Plus lots more.
I really appreciate your support and a cup of coffee goes along way. Helping me to make more videos to help you
Any donation in my “TOOL BOX FUND” is amazing and really appreciated
www.paypal.com/donate/?cmd=_s-xclick&hosted_button_id=AQE6ZCCN5VMLA
Please click "THUMBS UP" and "SUBSCRIBE". Click on the "BELL" if you would like a notification next time I upload a new help Video
"SHARE" me with your friends
Find MORE HELP on my Web Site, where all my videos are categorised to make them easy to find.
With links to products and parts I recommend
www.markballard-ltd.com
You can leave a message in the comments, your feed back is always appreciated. Thank You
00:00 - How to install or repair a radiator air vent and blanking plugs.
03:01 - Why is my radiator air vent / blanking plug leaking?
04:09 - Radiator air vent and blanking plug rubber o ring.
04:45 - Importance of NO paint in the radiator plug holes.
06:17 - Where to buy new radiator blanking plug and air vent.
06:34 - Is the radiator air vent supposed to move?
06:44 - Can you fix old radiator air vents?
07:06 - Old Radiator bleed keys are different sizes.
07:23 - How to repair a leaking radiator air vent or blanking plug.
08:46 - How to remove pressure in a radiator.
10:05 - Mark Ballard tool box Fund.
10:14 - Use PTFE tape to repair a radiator plug.
Amazon Shopping
www.markballard-ltd.com/recommends/radiator-bleed-valve-blanking-plug/
www.markballard-ltd.com/recommends/radiator-bleed-keys-different-sizes/
Links To Other Help Videos.
VIDEO: How to remove a radiator for decorating, 2 different ways.
ua-cam.com/video/aHQsNP_cowM/v-deo.html
VIDEO: How to replace a leaking radiator valve. With out draining the system: Part 1.
ua-cam.com/video/mjsPZirB9Cg/v-deo.html
VIDEO: How and Why you should add "INHIBITOR" to your heating system. Including "System Cleaner" and other "Chemicals"..
ua-cam.com/video/ezn1qYzLQ7E/v-deo.html
VIDEO: How to flush Out a Radiator. The Best Way, Getting the Best Results
ua-cam.com/video/bmc4mzBbVT0/v-deo.html
VIDEO: How to Replace a Radiator with Out Draining the System.
ua-cam.com/video/bHSVbTwQSxw/v-deo.html
VIDEO: How to bung up a loft tank.
ua-cam.com/video/LakrAp8__SI/v-deo.html
VIDEO: How to Fix a Radiator NOT Getting Hot! Thermostatic Valve Stuck.
ua-cam.com/video/GhWp2ef_2pY/v-deo.html
Video: How to Paint/Spay your Radiator. with a sparkle finish.
ua-cam.com/video/bdjcBQo7cog/v-deo.html
VIDEO: How to Get a Radiator working and Hot Again, Everything I would do.
ua-cam.com/video/O3Sg2b3Hjec/v-deo.html
VIDEO: Radiator NOT GETTING HOT Because of Blockage in the Pipework.
ua-cam.com/video/HCKNZNyxyWs/v-deo.html
VIDEO: How To Remove a Olive, Five Different Ways To Remove a Old Olive Off a Pipe
ua-cam.com/video/R3NlOY1lBtU/v-deo.html
VIDEO: How to Fit Radiator Valves & How NOT to Fit a Radiator Valve. Fixing Leaking Radiator Valves.
ua-cam.com/video/VecErMR29No/v-deo.html
VIDEO: How to Balance your Heating System to make it more efficient. Which will REDUCE YOUR GAS BILL.
ua-cam.com/video/AhVoT55lhSw/v-deo.html
VIDEO: How to Install the Hive Thermostat Mini, Explained in Detail Wiring, Pairing, Factory Reset.
ua-cam.com/video/542fXcLUliY/v-deo.html
VIDEO: How to Install the Hive Thermostat Mini into a Combination Boiler.
ua-cam.com/video/GCi1VyP1Hac/v-deo.html
VIDEO: How to Install the Hive Thermostat Mini Internet Hub.
ua-cam.com/video/vNpXZ-cnU9w/v-deo.html
VIDEO: How to Operate Honeywell T3R Programmer
ua-cam.com/video/wGPKZuo6AFM/v-deo.html
VIDEO: How to Install and add Inhibitor, Magna Clean Professional 2
ua-cam.com/video/SxrIPN_p22w/v-deo.html
Video: Easiest way to Add Inhibitor into a Vaillant Filter or Spirotech filter or Any Filter with a 3/4 Drain Point
ua-cam.com/video/H6-qdJjKek0/v-deo.html
VIDEO: How to Fix Vaillant ecoTEC Plus F.22 / 0.0bar Safety switch off low water pressure.
ua-cam.com/video/pC837Ogc0fc/v-deo.html
VIDEO: How to Fix F75 on a Vaillant & Glow-Worm Boiler, Plus Why Your Boiler is Tripping Out with F75
ua-cam.com/video/48hsc81Ucko/v-deo.html
VIDEO: How to clean Vaillant Filter Version 2. Vaillant Protection Kit.
ua-cam.com/video/P8vim3NfHEM/v-deo.html
VIDEO: How to clean the Magna Clean Professional 1
ua-cam.com/video/dwbFx0wG3lk/v-deo.html
VIDEO: 10 Money Saving Heating Tips. Simple Things You Can Do Which Will Improve Efficacy Save Gas / Money.
ua-cam.com/video/yDwiqgqdvoc/v-deo.html
Recommended Tools.
VIDEO: Einhell Classic TC VC1930S Wet & Dry Vacuum Review, 30L 1500watt.
ua-cam.com/video/y4hY7zkAYuQ/v-deo.html
Shopping (Amazon): Water Vacuum. I use this vacuum daily. Highly Recommended. www.markballard-ltd.com/recommends/einhell-classic-tc-vc1930s-30l-wet-dry-vacuum-cleaner-230v/
“As an Amazon Associate I earn from qualifying purchases”
The Gas Safe Register.
www.gassaferegister.co.uk
Переглядів: 939

Відео

How to Remove Radiator for Decorating, Flushing Out, Painting or Removed for Good, Tips & TricksHow to Remove Radiator for Decorating, Flushing Out, Painting or Removed for Good, Tips & Tricks
How to Remove Radiator for Decorating, Flushing Out, Painting or Removed for Good, Tips & Tricks
Переглядів 91824 дні тому
In this video I will show you Two Different ways to remove a radiator whether you want to decorate behind it, paint/spray and change the colour of the radiator, flush it out or just remove the radiator because its no longer needed. I will show you with step by step easy to follow instructions how to do this with little fuss or mess. Plus lots more. I really appreciate your support and a cup of ...
Replacing Your Old Programmer & Room Thermostat with Hive Active Heating & Wiring up the Zone ValvesReplacing Your Old Programmer & Room Thermostat with Hive Active Heating & Wiring up the Zone Valves
Replacing Your Old Programmer & Room Thermostat with Hive Active Heating & Wiring up the Zone Valves
Переглядів 8382 місяці тому
I will show you how to wire up zone valve on a central heating system and replace you old programmer and room thermostat with "Hive Active Heating" Smart heating Controls. As usual, I will give you tips along the way and lots more. I really appreciate your support and a cup of coffee goes along way. Helping me to make more videos to help you Any donation in my “TOOL BOX FUND” is amazing and rea...
How to Pair Additional Hive Thermostats to Your Existing Hive Active Heating Creating 2/3 New ZonesHow to Pair Additional Hive Thermostats to Your Existing Hive Active Heating Creating 2/3 New Zones
How to Pair Additional Hive Thermostats to Your Existing Hive Active Heating Creating 2/3 New Zones
Переглядів 1,2 тис.3 місяці тому
Adding More Zones, I will show you TWO ways to pair a new "Hive Thermostat and Receiver Unit" to an existing "Hive Active Heating System" to create one or two new heating zones. Easy to follow step by step instructions. As usual, I will give you tips along the way and lots more. I really appreciate your support and a cup of coffee goes along way. Helping me to make more videos to help you Any d...
How to Install the Hive Active Heating, Hub, Receiver, Thermostat & Smart Phone AppHow to Install the Hive Active Heating, Hub, Receiver, Thermostat & Smart Phone App
How to Install the Hive Active Heating, Hub, Receiver, Thermostat & Smart Phone App
Переглядів 10 тис.3 місяці тому
I will show you step by step how to install Hive Active Heating on your combination boiler or other systems. Start with the hub get that linked to the Hive Server on line. Then I add the Receiver Unit, show you some wiring options and link it to the Hive Hub. Next is the Hive Thermostat Mini, link them all together. Finally install the Hive Active Heating App on your Smart Phone and link it to ...
How and Why You Should Add "INHIBITOR" to Your Heating System. Or "System Cleaner" / "Chemicals"How and Why You Should Add "INHIBITOR" to Your Heating System. Or "System Cleaner" / "Chemicals"
How and Why You Should Add "INHIBITOR" to Your Heating System. Or "System Cleaner" / "Chemicals"
Переглядів 2,3 тис.4 місяці тому
Adding "Inhibitor" or "System Cleaner" or maybe "Leak Sealer" to your central heating system. I will show you the best ways to add chemical to your heating system, Combi and Traditional Systems. This is a update to my original video and I answer all you questions form the first video so you get all the information you need to get the job done the best way posable with no stress or mess. Plus lo...
How to Refit a Radiator After Decorating or Plastering, Tips and Tricks so You Don't Get Any LeaksHow to Refit a Radiator After Decorating or Plastering, Tips and Tricks so You Don't Get Any Leaks
How to Refit a Radiator After Decorating or Plastering, Tips and Tricks so You Don't Get Any Leaks
Переглядів 1,2 тис.4 місяці тому
In this video I am refitting a radiator after some decorating work as been done behind it. I will show you with step by step instructions how to prepare your radiator valves so you don't get any leaks. Refilling so you don't get problems with air in the system. Plus lots more. I really appreciate your support and a cup of coffee goes along way. Helping me to make more videos to help you Any don...
How to Install the Hive Thermostat Mini on a Traditional Heating System, Step by Step Instructions.How to Install the Hive Thermostat Mini on a Traditional Heating System, Step by Step Instructions.
How to Install the Hive Thermostat Mini on a Traditional Heating System, Step by Step Instructions.
Переглядів 2,6 тис.5 місяців тому
Hive Thermostat Mini installed on a traditional system where you have a large hot water tank and additional controls. I will explain the wiring in detail and show your wiring options. Show you how to pair the units together & if your have difficulty Pairing/Linking/Binding the two units together, I will explain how to factory reset the Hive Thermostat Mini, which will then let it pair to the re...
How to Install the Hive Thermostat Mini on a Combination Boiler, Simple Step by Step Instructions.How to Install the Hive Thermostat Mini on a Combination Boiler, Simple Step by Step Instructions.
How to Install the Hive Thermostat Mini on a Combination Boiler, Simple Step by Step Instructions.
Переглядів 7 тис.6 місяців тому
I will show you how to install the Hive Thermostat Mini on a combi boiler. Explain the wiring on the receiver unit and the wiring on the combi boiler. Show you how to pair the units together, if your have difficulty Pairing/Linking/Binding the two units together, I will explain how to factory reset the Hive Thermostat Mini, which will then let it pair to the receiver unit. Plus a quick look at ...
How to Install the Hive Thermostat Mini, Explained in Detail Wiring, Pairing, Factory Reset.How to Install the Hive Thermostat Mini, Explained in Detail Wiring, Pairing, Factory Reset.
How to Install the Hive Thermostat Mini, Explained in Detail Wiring, Pairing, Factory Reset.
Переглядів 16 тис.7 місяців тому
If you are having difficulty Pairing/Linking/Binding the two units together, I will explain exactly how to do that and if that's not working. How to factory reset the Hive Thermostat Mini which will then let it pair to the receiver unit. I explain how to wire the receiver unit up and all the different wiring option you can use. I'll show you a couple of stand options. Hive Mini Stand and a much...
Everything You Can Do To Get a Radiator Working Again, So It's Nice & Hot. All the Things I Do.Everything You Can Do To Get a Radiator Working Again, So It's Nice & Hot. All the Things I Do.
Everything You Can Do To Get a Radiator Working Again, So It's Nice & Hot. All the Things I Do.
Переглядів 2,6 тис.7 місяців тому
I will show you everything that I do to get a radiator working again. From the basic bleeding, checking valves are open, thermostat not stuck closed to the more advanced taking valves off and flushing out pipework to remove a blockage. And lots more. I really appreciate your support and a cup of coffee goes along way. Helping me to make more videos to help you Any donation in my “TOOL BOX FUND”...
Radiator NOT GETTING HOT Because of Blockage in the Pipework. Finding & Removing Blockage. FIXEDRadiator NOT GETTING HOT Because of Blockage in the Pipework. Finding & Removing Blockage. FIXED
Radiator NOT GETTING HOT Because of Blockage in the Pipework. Finding & Removing Blockage. FIXED
Переглядів 11 тис.8 місяців тому
This incredible blockage in the pipework was accidentally made by the bathroom fitter who installed the radiator some two years previously to my visit and the radiator had only got luck warm because of the blockage. Once I found and removed the blockage the radiator worked fine and got nice and hot. I really appreciate your support and a cup of coffee goes along way. Helping me to make more vid...
How to RESET the Vaillant ecoTEC Plus Boiler with a touch Screen Display F29, F28, F75, F61, F62How to RESET the Vaillant ecoTEC Plus Boiler with a touch Screen Display F29, F28, F75, F61, F62
How to RESET the Vaillant ecoTEC Plus Boiler with a touch Screen Display F29, F28, F75, F61, F62
Переглядів 10 тис.8 місяців тому
I will show you how to RESET your "Vaillant ecoTEC Plus Boiler" so you can get it back up and running again if it showing a fault code like F29, F28, F75, F61, F62 . Also going through some common faults which I regally come across and what you can do with these faults to get your boiler running again, if posable. I really appreciate your support and a cup of coffee goes along way. Helping me t...
How to Fix F22 / F.22 on a Vaillant Boiler, How to Top-Up Your Vaillant Combi Boiler & System BoilerHow to Fix F22 / F.22 on a Vaillant Boiler, How to Top-Up Your Vaillant Combi Boiler & System Boiler
How to Fix F22 / F.22 on a Vaillant Boiler, How to Top-Up Your Vaillant Combi Boiler & System Boiler
Переглядів 5 тис.9 місяців тому
I will show you how to fix the F.22 fault on your Vaillant boiler which has the touch screen display. This video is also for Vaillant System Boilers and the older Vaillant ecoTEC Pro & Plus Boilers. How often you you be topping up your boiler. Because to often is really, really bad for you boiler and system. I will show you why. I really appreciate your support and a cup of coffee goes along wa...
How to Install MyVaillant Connect + SensoROOM Smart Heating Control, Pros & Cons, Efficiency & MoreHow to Install MyVaillant Connect + SensoROOM Smart Heating Control, Pros & Cons, Efficiency & More
How to Install MyVaillant Connect + SensoROOM Smart Heating Control, Pros & Cons, Efficiency & More
Переглядів 14 тис.9 місяців тому
I install TWO of the "MyVaillant Connect" smart heating controls onto the New "Vaillant ecoTEC Plus Combination Boiler" with touch screen. One was on a Android Phone the other on Apple System. I show you how to set up the App and connect to the Wi-fi as both systems are different. I did come across problems when connecting onto the wi-fi on both installation. But got them all working Ok. How en...

КОМЕНТАРІ

  • @muhammadaslam1167
    @muhammadaslam1167 17 годин тому

    Very good explaining 👌🏻👌🏻👌🏻 I've learnt allot

  • @redbudgieuk
    @redbudgieuk День тому

    Hi Mark, so you open the return first for a short period and then the inlet?

  • @all4heatinggaslimited40
    @all4heatinggaslimited40 День тому

    Thank you Mark

  • @cnoriga
    @cnoriga День тому

    First at all thanks for this video which I found very informative on how to operate the boiler. I recently had an Ecotect Sustain installed and I found that the boiler wakes up when opening any cold water tap in the house. The fan starts to spin up, you can see the flame symbol for a short seconds and then disappears and eventually the fan stops spinning. I have never seen or expected this behaviour with previous combi boilers, Is this normal?

  • @zappa248
    @zappa248 2 дні тому

    Is there a way to call for hot water whilst waiting for a broken flow turbine repair?

  • @mohammadmoshtagh3746
    @mohammadmoshtagh3746 2 дні тому

    Thank you for very informative videos, I have a glow worm flexicom manufactured 2012 . I have put a new Pcb and is flashing F70 fault. Could you please advise on how to program the pcb. Thanks in advance

  • @darthghetts
    @darthghetts 3 дні тому

    Thank you for your help once again!

  • @davidwatkins9555
    @davidwatkins9555 3 дні тому

    My receiver has a red light it's a stand alone

  • @staceycurtis8983
    @staceycurtis8983 3 дні тому

    I've just gone in the airing cupboard and checked everything and the big black magnet has fallen off. I've put it back on but it keeps slipping? what does this mean?

  • @TB-gz9zt
    @TB-gz9zt 4 дні тому

    Thank you so much. We have a Glow Worm Easicom 24. If anyone has this boiler there is only one leaver instead of two and i had to turn it anti clockwise (not clockwise) water pressure started working imeediately and hot water returned in a few mins. Side note, be mindful of your thermostat, if its actually warm weather like the summer make sure your thermostat is set to high so it triggers the boiler to work. I.e if your house temperture is 18 degrees and the your thermostat is set to 16 in the summer, automatically your boiler wont be triggered to work. Quick fix is increase it to a high tempature and it will resume working. Thanks Again!

  • @MarieN8959
    @MarieN8959 4 дні тому

    How do I set a timer on a C24 please 🙏

  • @vicrobinson1366
    @vicrobinson1366 5 днів тому

    Great information thank you👍👏

  • @TonyMontana-os8ri
    @TonyMontana-os8ri 5 днів тому

    I have done over about 30 turns with tape and still can’t tighten properly

  • @zenastronomy
    @zenastronomy 6 днів тому

    my combiboiler keeps pumping something out for 30sec every 8min. It isn't turning on like heating water as flame doesn't turn on. And preheat function should be switched off. As i selected off on the controller. Boiler guy came and said it was flow valve filled with limescale. He replaced it, and it now turns on for 3 seconds every 8min. Is that normal, Any idea why it keeps venting something for 3 seconds every 8min?

  • @user-ye6cz3wo5t
    @user-ye6cz3wo5t 6 днів тому

    Do less talking and more physical demonstration .

  • @kaursohal97
    @kaursohal97 7 днів тому

    Working yeah thank you so much🎉

  • @markedwards4656
    @markedwards4656 7 днів тому

    trying to rebind T3H700RF0096-1 it only will give me 14B not 14C to bind can not find any instruction

  • @crazygamer4879
    @crazygamer4879 7 днів тому

    Thank you for your video it helped me to install the towel radiator yipeeee😂

  • @RxchLJ
    @RxchLJ 8 днів тому

    Who needs a man 😅 thanks Mark 🫶🏾

  • @sid111sid111sid111
    @sid111sid111sid111 8 днів тому

    Very useful, thanks 🙏

  • @carlsimpson4875
    @carlsimpson4875 8 днів тому

    Good video well explained, I have a lazy capacitor on solar system pump it works for four or five days but then it gives in and I have to manually get the pump running by tweaking the speed switch on the pump. I’m going to replace the capacitor and see if it solves the issue.

  • @jameshenderson5385
    @jameshenderson5385 8 днів тому

    Just had mine installed together with the whole house heating system, all with a 12 year guarantee..

  • @shubhambadgujar9943
    @shubhambadgujar9943 9 днів тому

    sir I have a question, this aqua signal ignites the gas boiler but is it a continous signal or just a one time ? the reason i am asking this is , i am doing a project and i have connected a electric heater to heat water but i dont want to run both heaters at same time and want to save my gas money so i figured if i just block this aqua signal , i can stop gas boiler from igniting ! so please if you reply it will be a huge help ! thanks in advance!!

  • @markbarlow9955
    @markbarlow9955 9 днів тому

    Which video is it that explains how to fix the stuck check valve issue with the boiler top up? Thanks

  • @waliza001
    @waliza001 9 днів тому

    Piece of crap without magnet

  • @Empress4ever
    @Empress4ever 9 днів тому

    What if your hot water is on 65 and still not hot enough while having a bath?

  • @Shabzana
    @Shabzana 9 днів тому

    This is great, but I can't see the tap.icon anywhere, doubled tapped the left button and a timer shows up. Am at my wit's end here. Pls helppppoo

  • @davidcoleman6032
    @davidcoleman6032 10 днів тому

    Superb video Mark! Many thanks for posting. 👍

  • @ascot4000
    @ascot4000 11 днів тому

    Balancing radiators looks an easy task with a handful of radiators. I've got 22 of them and I got dizzy just trying (and failing) to work out the order they are in the heating circuit, let alone refining anything. Having low flow temps may makes it all very efficient but it adds another level of complication to the process. In an old v-hot design you could simple feel the flow and return and the heating pattern on a radiator just by feel alone.

  • @Noname4now2025
    @Noname4now2025 11 днів тому

    If i press - and + together whats happend?

  • @MIMI232
    @MIMI232 11 днів тому

    This boiler is connected to a device that sends a WiFi signal to the thermostat does this burn a lot of energy?

  • @aftermath_euphoria
    @aftermath_euphoria 12 днів тому

    Great video! We've recently had one of these installed and was worried great, but in the last week on eco mode the water will heat up and almost immediately start cooling down again so we're not getting consistent hot water when we want to do the dishes or run a bath. Any advice?

  • @DunkingJaffaCakes
    @DunkingJaffaCakes 12 днів тому

    I had a Logic combi when we moved in and the central heating temperature knob did nothing - As it happened there was a weather compensator installed which takes that control away and the radiator temps are set automatically by the system based on the outside temperature. This is important to note as some people may be unaware that their CH knob is doing nothing. Turns out it was a really crappy system because unless it was near zero outside the radiators were never hot enough to heat the house.

  • @danskye
    @danskye 12 днів тому

    Worked a treat , now for a nice shower. Thanks man :)

  • @tatiananotami1861
    @tatiananotami1861 13 днів тому

    massive thanks! managed to reconnect Hive Mini to the receiver and saved on the gas engineer fees! 🎉🎉🎉

  • @tauqiranjum1434
    @tauqiranjum1434 14 днів тому

    I really like your videos . Very helpful Could u plz do all this procedure with one thing connected. Then it’s easy to learn the wiring

  • @vinithalekshmi1
    @vinithalekshmi1 14 днів тому

    Urgent how to reduce pressure😢

  • @abdukadirnur6110
    @abdukadirnur6110 14 днів тому

    I get the heater on and no hot water. Can anyone help

  • @DilnozaUK
    @DilnozaUK 15 днів тому

    Thank you so much mate. You Saved lived❤❤❤

  • @zenastronomy
    @zenastronomy 16 днів тому

    mine keeps turning on for 25 seconds, i can hear it doing something like pumping air or gas or something out. and then stops for 2-3min then repeats. everything switched off in the flat. wondering if that normal or an issue like water leak could cause such a behaviour? or is this normal and I'm just noticing it now and hadn't before? I'm not seeing the tap led lighting up when it starts pumping the air out.

  • @tomclarke1768
    @tomclarke1768 17 днів тому

    Not only does this guy know his stuff..... he's also about the best & most articulate communicator I've ever come across. 👍

  • @robshorts
    @robshorts 17 днів тому

    Thanks for that, I'm certainly going to check mine are tight enough, I've replaced some very old radiators over the last few years and am about to replace another.

  • @YGriffiny
    @YGriffiny 18 днів тому

    Well done mate. Thanks a million. Top man.

  • @richieakram
    @richieakram 18 днів тому

    Excellent vid and very informative .....thanks. How long roughly do you need to run the central heating system after installing the inhibitor for it to fully circulate?

  • @Andrew-fb2vo
    @Andrew-fb2vo 18 днів тому

    Amazing, thank you so much

  • @InternallyCoherent
    @InternallyCoherent 18 днів тому

    I just moved into a house that has this boiler and the previous owners didn't leave the manual behind, nor was the manual I found online very helpful. This video helped me to get things set up really quickly. Thank you for taking the time out to show people how to use this!

  • @allanford7767
    @allanford7767 19 днів тому

    I have a white triangle with exclamation mark I have reset boiler at the wall there’s a reset button but the triangle exclamation mark keeps coming back not sure what to do

  • @andreadealessi6750
    @andreadealessi6750 19 днів тому

    Thank you very much for this tutorial, Mark. My CM927 display is fully recovered. I can't believe my eyes. The only thing I did differently, after several attempts, was to put pressure with my fist on the whole screen while still hot. All numbers and letters are now showing as if brand new. Amazing. Cannot be more grateful.

  • @stephenkirk1154
    @stephenkirk1154 20 днів тому

    Just bought my first house and I’m trying to install my Hive mini set up into the existing ideal iMini boiler. It’s already set up with a Drayton Digistat+2 which is connected with a three chord flex but the earth wire isn’t connected to anything. My question is - will everything work fine if I just replace the Drayton with my hive and use the three chord flex and wire it up as you’ve shown ? What’s the benefit of using the switch wires ?

  • @jaredwaywood6876
    @jaredwaywood6876 20 днів тому

    Ive done this and its working!! However, there is a slight leakage on the pipe with a small drip. Will this stop?